News

safe escape routes

Fire-Safe Galleries as Escape Routes: What Do You Need to Know?

In an emergency, safe escape routes are essential. Strict fire safety requirements apply when designing walkways in apartment buildings. These escape routes must comply with the 2012 Building Decree (WBDBO), NEN standards, fire department guidelines, and the Working Conditions Decree. In this article, we explain how to ensure your gallery project is fire-safe using Envirodeck solutions from the Fiberplast Group.

Safe Evacuation Routes: Circular and Sustainable

 

Essential Fire Safety Requirements

WBDBO (Resistance to Fire Penetration and Fire Spread)

  • Default: 30 minutes
  • High-rise buildings (>70 m): 60 minutes (Building Code, Art. 2.124–2.125)

 

Tread Fire Rating (EN 13501-1)

  • Buildings ≤13 m: Cfl-s1-d0
  • Buildings at >13m: Bfl-s1-d0 (mandatory, unless an exception is approved following a risk analysis)

 

Smoke Development

  • Minimum smoke class S1 (S2 only for low-rise buildings, subject to approval)
  • Smoke exhaust systems in accordance with NEN 6098

 

Evacuation Route Requirements

  • Minimum width: 1.1 m (NEN 6088)
  • Emergency lighting in accordance with NEN 3011

Envirodeck: The ultimate solution for fire-safe walkways

Envirodeck decking boards offer the right fire rating for every project:

  • Low-rise buildings (≤13 m): Classic Pro Deck & Solid Deck (Cfl-s1-d0)
  • High-rise buildings (>13 m): Mega Deck, Classic Pro Deck, and Solid Deck in the Fire Resist version (Bfl-s1-d0)

 

Additional safety measures:

  • Minimum slip resistance R10, optimal R11 (NEN-EN 13036-4)
  • Fire-resistant substructure
  • Proper drainage (minimum 1% slope, Building Code, Art. 3.48)

Self-supporting structures versus concrete galleries

Self-supporting structures

  • Construction: Consists of a hardwood or metal joist system (s1) onto which Envirodeck decking boards are installed.
  • Fire Safety Requirements:
    • A fire-resistant panel (minimum EI30) is required beneath the joist layer to ensure a 30-minute fire resistance rating (in which case, the s1 smoke class requirement for the hardwood joist layer may be waived under certain conditions).
    • Recommended materials: Fermacell Powerpanel H2O, Promatect-H, or Swisspearl (provided they are EI30-certified); waterproof versions are recommended.
    • No flammable droplets allowed (d0 classification required).
  • Advantages:
    • Lighter in weight, suitable for renovation projects, conversions from office to residential buildings, and expansions.
    • Flexible in design and easier to customize.
  • Points to Consider:
    • Must be properly supported with a sufficiently strong beam layer.
    • Special attention must be paid to water runoff and drainage.

 

Concrete planter boxes

  • Construction: A solid concrete floor, such as a apartment building gallery, onto which Envirodeck decking boards are installed.
  • Fire Safety Requirements:
    • Concrete meets the WBDBO standard of at least 30 minutes by default, so no additional fire-resistant panel is required.
    • Only the walking surface itself must meet the appropriate fire rating (Cfl-s1-d0 or Bfl-s1-d0, depending on the height of the building).
    • A lightweight aluminum substructure is permitted, optionally mounted on height-adjustable RAPTOR floor supports.
  • Advantages:
    • Stable and robust construction requiring less maintenance, with immediately accessible safe escape routes.
    • Reduced risk of deflection or structural degradation.
  • Points to Consider:
    • It can be heavier and requires a sturdy base.
    • Slopes and drainage must be carefully designed to prevent puddles from forming.

Please note: Wood in evacuation routes? Only if certified!

Standard wood does not automatically meet smoke class S1 requirements. For galleries, we recommend:

  • Certified planks (Cfl-s1-d0 for low-rise buildings and Bfl-s1-d0 for high-rise buildings)
  • Fire-retardant hardwood with smoke class S1
  • Always request test reports (EN 13501-1)

 

Sources & more information:

Conclusion: Creating Safe Escape Routes

By complying with fire safety requirements (WBDBO, smoke class S1), ensuring proper slope (1–2%) and drainage, and selecting the appropriate joist system or concrete subfloor, you can create a safe and low-maintenance escape route.

Want to learn more? 📞 Contact our consultants for project-specific advice!

Fiberplast – Innovative solutions for fire-safe architecture 🌐 www.fiberplast.nl | 📞 Contact 0512 544 503

 

You can verify these requirements through the following official sources:

1. 2012 Building Code (Dutch legislation)

  • Article 2.129 (Fire Safety of Escape Routes):
    https://wetten.overheid.nl/BWBR0030941/2023-07-01#Chapter2_Section2_Article2.129
    This states that materials in escape routes of buildings >13m must meet “fire class Bfl” (combined with smoke class s1).

2. NEN 13501-1 (European fire classification)

  • Official standard for fire classes (Bfl, Cfl) and smoke development (s1, d0):
    https://www.nen.nl/nen-en-13501-1-2018-en-248540
    Confirms that natural wood rarely achieves Bfl-s1-d0 without treatment.

3. Dutch Fire Department / IFV (Practical Guidelines)

  • Fire Safety Handbook (chapter on escape routes):
    https://www.ifv.nl/kennisplein
    Describes why high-rise buildings impose stricter requirements on smoke development (s1).

4. KIWA / SKH (certification bodies)

A frequently asked question is: Does natural wood meet the Bfl-s1-d0 standard?

  • Test reports (such as this one from TNO) show that untreated wood:
    • Ignites too quickly (no Bfl classification).
    • Smoke class S1 requires fire-retardant additives.
Conclusion on Safe Escape Routes

The combination Bfl-s1-d0 is required for galleries >13 m (usually >5 stories), and natural wood can only achieve this with special coatings (e.g., Pyrohout). Always consult:

  1. The Building Code (legal basis)
  2. Supplier Certificates (KIWA/SKH)
  3. Fire safety advice for each project.
Fiberplast Group’s Sustainable Circular Solutions

Fiberplast Group conceives, develops, manufactures, and supplies circular building materials for future-proof construction.

Our sustainable materials have been used for nearly 20 years in the circular construction of (fire-resistant) facades, decking, patios, roof walkways, and foundations. Our products are always made entirely from renewable or recycled raw materials. The composites are partially or almost entirely biobased, and the rubber products are always made from recycled rubber.

By purchasing our products, you’re always helping to reduce waste and prevent deforestation. All of our products have a long service life, are reusable, and are 100% recyclable!

Check out all our sustainable solutions at www.fiberplast.nl

Share

Related posts

New European Fire Safety Standard EN 16755:2026: What Does It Mean and What Does It Entail?

From now on, architects, contractors, facade builders, and project developers must not only take into account a product’s fire rating and the construction of, for example, a wall (End-Use), but also whether those performance characteristics are maintained throughout the product’s service life. The new European fire safety standard EN 16755:2026 sets additional requirements for this. […]

New European Fire Safety Standard EN 16755:2026

RIWOOD Featured in Jongeneel and PontMeyer’s Facade Brochure

RIWOOD fire-resistant siding is featured in the new facade brochures from Jongeneel and PontMeyer. The building materials wholesalers Jongeneel and PontMeyer (both part of the TABS Group) have released new facade brochures. In these brochures, they present a wide range of professional solutions for sustainable and future-proof facades. RIWOOD is also prominently featured in them. […]

Jongeneel and PontMeyer Facade Brochures

Biobased Sound Barriers, Sustainable Road Design

As early as 2018, Fiberplast Group supplied Envirodeck Soundboard for a 400-meter biobased noise barrier at locations including Vroonermeer Noord along the N254. Sustainable, biobased Envirodeck is a wood composite made entirely from waste streams. No new raw materials are used to make this sustainable product. For years now, interest in products with a low […]

biobased sound barrier

From the Building Code to the BBL: What Has Changed Regarding Escape Routes?

Emergency Exits and Fire Safety: What Does That Mean for Floor Finishes? In the event of a fire, every second counts. That is why Dutch building codes impose strict requirements on escape routes: the paths along which people must be able to safely exit a building. Not only the length, width, or location of an […]

BBL: Escape Routes and Fire Safety

Designing Fire-Safe Escape Routes

In high-rise buildings, it is essential that safe escape routes be provided. Many of these escape routes naturally run through the galleries and stairwells, as these are already in place by design. The safety of these escape routes must be guaranteed, which is why there are strict requirements that escape routes must meet. The so-called […]

Emergency exit, evacuation route

STABU Specification Texts for Facades, Decks, and Foundations (Industry Standard)

Architects and specification writers want to be able to include materials in specifications quickly, accurately, and without risk. That is why Fiberplast Group provides STABU specification texts for its key systems in accordance with the Ketenstandaard methodology. With our specifications, you can easily specify fire-safe, circular, and technically sound solutions for facades, decking, and foundations—fully […]

Stabu Chain Stand

Fiberplast and Circular Construction

Circular Construction with Fiberplast Biobased and Circular Building Materials for the Built Environment The construction industry is facing a major transition toward circular construction and biobased materials. Governments, architects, and clients are increasingly seeking sustainable alternatives to traditional building materials that have a lower environmental impact. For many years, Fiberplast Group has been supplying innovative […]

Circular economy, biobased products

Spring Agreement 2.0: Improving Detachability

Over the past few months, Fiberplast Group has been involved in developing the Spring Agreement 2.0. The goal of the Spring Agreement was to improve the demountability of building materials and to promote circularity in the broadest sense of the word. The Spring Agreement 2.0 is a multi-year program aimed at embedding circular industrial construction […]

Circular logo 940x560

Price Alert

Price Alert: Transportation and Raw Materials Due to the current geopolitical unrest in the Middle East, we are seeing sharp increases worldwide in both transportation costs and raw material prices. Fiberplast Group is also directly feeling the effects of this. In particular, diesel, ocean freight, and various raw materials (such as PVC, polymers, and additives) […]

Euro symbol
We zoeken naar meer..
Call me back

Want to learn more about our products or what we can offer? 

Please provide your contact information, and we’ll get back to you as soon as possible.

Fiberplast Group does not sell directly to individuals; you can order tile and floor underlays from our online store at www.tegeldrager.nl

Request a Sample

Feel free to request one or more samples with no obligation and let yourself be inspired. If you’d like a specific type and/or color, please indicate that in the comments field below.

Fiberplast Group does not sell directly to individuals, with the exception of our online store at www.tegeldrager.nl, where you can purchase floor, deck, and tile supports.